Pressure Transducer | Industrial & OEM Pressure Transducers Manufacturer | Winsen

Winsen designs and manufactures industrial and OEM pressure transducers for gases and liquids. Our portfolio covers gauge, absolute, and differential types with analog (4–20 mA, 0–10 V, 0.5–4.5 V) and digital (I²C/SPI) outputs, wide ranges from micro-pressure to 100 MPa, and robust stainless-steel construction for long service life.

Overview & Working Principle

A pressure transducer converts fluid pressure into an electrical signal. Winsen integrates a stable sensing element (piezoresistive, capacitive, or piezoelectric), temperature compensation, and signal conditioning to deliver linear, low-noise outputs that are easy to read in PLCs, microcontrollers, or data acquisition systems.

Choose gauge for pressure relative to ambient, absolute for pressure relative to vacuum, and differential for the difference between two ports. For long cable runs and industrial noise environments, 4–20 mA is preferred; for low-power or MCU designs, ratiometric or digital outputs are ideal.

Diffused Silicon Pressure Sensor

Ceramic Pressure Sensor

Plastic Sealed Pressure Sensor

Diffused Silicon Pressure Transmitter

Ceramic Pressure Transmitter

Glass Micro-Fusing Pressure Transmitter

Pressure Sensor and Transmitter Comparison Overview

CategoryModelPower Supply / OutputDetection RangeAccuracy / NonlinearityPressure ReferenceOperating TemperatureShell MaterialRemarks
Diffused Silicon Pressure SensorWPAK701.5mA / mV-100kPa ~ 0 ~ 10kPa…10MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃High versatility, compact design
WPAK691.5mA / mV-100kPa ~ 0 ~ 10kPa…10MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Similar to WPAK70
WPAK681.5mA / mV-100kPa ~ 0 ~ 10kPa…100MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Extended range version
WPAK671.5mA / mV0 ~ 10kPa…2.5MPa≤±0.3%FSDifferential Pressure-40℃ ~ 120℃For differential applications
WPAK661.5mA or 10V / mV6MPa…60MPa≤±0.3%FSSealed Gauge-40℃ ~ 120℃Sealed design for higher ranges
WPAK651.5mA or 10V / mV-100kPa ~ 0 ~ 10kPa…16MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃General-purpose sensor
WPAK641.5mA or 10V / mV-100kPa ~ 0 ~ 10kPa…25MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Moderate range coverage
WPAK63J1.5mA / mV-100kPa ~ 0 ~ 10kPa…100MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃J-type version for special mounting
WPAK631.5mA or 10V / mV-100kPa ~ 0 ~ 10kPa…100MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Versatile with wide range
Ceramic Pressure SensorWPAH012–20V / mV0 ~ 200kPa…40MPa≤±0.3%FS-40℃ ~ 125℃High chemical resistance
Plastic Sealed Pressure SensorWPAS12Digital and analog15–115kPa-40℃ ~ 125℃Cost-effective, compact
WPAS02Digital and analog10kPa ~ 100kPa-20℃ ~ 80℃Basic sensor for air/gas
WPAS01Digital and analog10kPa ~ 100kPa-40℃ ~ 125℃Robust high-temp tolerance
Diffused Silicon Pressure TransmitterWPCK814–20mA, RS4850 ~ 1m…200mH₂O±0.5%FS / ±1%FSGauge PressureStainless steelFor deep-level and tank level measurements
WPCK624–20mA (Optional)0 ~ 35kPa…25MPa±0.5%FSGauge / Absolute / Sealed GaugeStainless steelWidely compatible, thread options
WPCK084–20mA, RS4850 ~ 200mH₂O±0.5%FSGauge PressureStainless steelExplosion-proof version
WPCK074–20mA, 0.5–4.5V, 0–5V, 1–5V, 0–10V, 1–10V-100kPa ~ 0 ~ 10kPa…100MPa±0.5%FSGauge / Absolute / Sealed GaugeStainless steelFull-range output types
WPCK050.5–4.5V, 0–5V, 1–5V, 0–10V, 1–10V-100kPa ~ 0 ~ 10kPa…100MPa±0.5%FSGauge / Absolute / Sealed GaugeStainless steelVoltage output options
WPCK03I²C, 4–20mA, 0.5–4.5V and more-100kPa ~ 0 ~ 10kPa…100MPa±0.2%FS, ±0.5%FS (custom)Gauge / Absolute / Sealed GaugeStainless steelFlexible signal types, high accuracy
Ceramic Pressure TransmitterWPCH040.5–4.5V (Customizable)0.2MPa…40MPa0.1%FS (Default)Stainless steelHigh precision ceramic core
WPCH014–20mA, 0/1–5/10V, 0.5–4.5V0.2–5MPa0.1% ~ 5.0%FS (Default 2.0%)Stainless steelCustomizable, versatile outputs
WPBH01Proportional voltage (0.5–4.5V)2–400 bar (Customizable)0.5%, 1%, 2% (Default), 3%Stainless steelBroad pressure range
Glass Micro-Fusing TransmitterWPCK89Digital and analog0 ~ 100 / 150 / 250 / 500 psig±1%FSStainless steelExtremely robust and thermally stable

Selection Guide

Use this quick matrix to choose the right transducer for your program. Our engineers can finalize the stack-up and calibration once your operating conditions are known.

Use CaseRecommended TypeTypical RangePreferred OutputWetted MaterialsProcess Connection
Hydraulics / pressesGauge / High-pressure10–100 MPa4–20 mA or 0–10 VSS 316L, mineral oil fillG1/4, 1/4-NPT, M14×1.5
Air compressorsGauge0–1.6 / 2.5 / 4 / 10 MPa4–20 mASS 304/316LG1/4, 1/4-NPT
Vacuum systemsAbsolute0–100 / 200 / 300 kPa abs0.5–4.5 V or I²CSS 316LG1/4, KF adapter
Clean room / filtersDifferential (low-range)±250 Pa to ±5 kPa0–10 V or 4–20 mASS + polymer portsBarbed 4–6 mm
Water & process liquidsGauge / Absolute0–600 kPa to 4 MPa4–20 mASS 316L, oil-isolatedG1/4, 1/2-NPT

Applications & Industries

Industrial & Manufacturing

Hydraulic presses, pneumatic lines, compressors, pumps, and test benches rely on stable transducers for control and safety interlocks.

Automotive & Off-Highway

Fuel, oil, brake, and hydraulic circuits demand shock-resistant, high-temperature designs and robust connectors.

HVAC & Clean Environments

Differential transducers monitor filters, ducts, and room pressurization in clean rooms and hospitals.

Energy & Utilities

Boilers, chillers, and gas distribution benefit from reliable feedback for PID control and alarming.

Water & Process

Water treatment skids, dosing systems, CIP loops, and process lines require corrosion-resistant wetted materials and IP-rated connectors.

Lab & Instruments

Benchtop analyzers and portable devices often use low-power absolute or differential transducers with digital outputs.

Why Global Clients Choose Us?

The company consistently adheres to the quality policy of “Fine Craftsmanship, Scientific Innovation, Pursuit of Excellence, and Value-Added Service.” By formulating production process control plans and work instructions, it has established a standardized, accountable, and regulated process management system. Additionally, the company has independently developed an MES production management system, enabling comprehensive and visual management across the entire workflow.

30+ YEARS OF EXPERIENCE

R&D, manufacture and sales of sensors and sensing solutions.

QUALITY GUARANTEE CONTINOUS IMPROVEMENT

Complete and rigid process flow control, coupled with significant improvements.

INTERNATIONAL MARKET

Deliver sensing products to more than 100 countries and regions.

STABLE SUPPLY CHAIN RELIABLE PRODUCTION

Core components not subject to constraints, advanced equipments for manufaturing and test.

R&D STRENGTH TECHNOLOGY INNOVATION

200+ patents, 180+ R&D team members, self-built labs for continous innovation.

ONE-STOP SERVICE

Professional consultation, fast delivery, 24 hours after-sales support.

Leading the Industry, Innovative & Controllable Technology

With robust R&D capabilities, we maintain sustained input in R&D and unwavering commitment to technological innovation. This not only ensures that we remain at the forefront of industry but also drives continuous innovation, leading the future trend of the sensing industry.

10% R&D Input

The average annual R&D input exceeds 10% of the annual revenue.

5+ R&D Layout

With Zhengzhou headquarters as the core, a nationwide R&D and innovation system is being established, encompassing cities of Shanghai, Wuhan, Shenzhen, and Taiyuan.

180+ R&D Team

There are over 180 R&D personnel, including more than 10 with doctoral degrees and over 50 with master's degrees, who have an average of more than 8 years of experience in sensor development.

20+ Experiment Types

Gas-related, Climatic Environment, EMC, Electrical Performance, Mechanical Performance, etc.

10+ Advanced Laboratories

CNAS Laboratory, MEMS Laboratory, UL Laboratory, Nanocomposite Materials Laboratory, etc.

400+ sets Leading R&D Equipment

Cube Storage, Die Bonder, Lithography Machine, Coating Machine, SMT Placement Machine, Automatic Probe Station, etc.

Request Consultation

    Success! Your message has been sent to us.
    Error! There was an error sending your message.

    Wechat

    Whatsapp

    Integration & Wiring

    For 4–20 mA (2-wire) loops, power with 12–36 VDC and maintain loop impedance within transmitter compliance. For 0–10 V outputs, a 12–36 VDC supply and high-impedance input (>10 kΩ) are recommended. Ratiometric 0.5–4.5 V devices should use low-noise 5 V and short sensor leads. I²C/SPI variants share digital ground with the host and need proper pull-ups and cable shielding.

    Example: 4–20 mA loop
    +24V  ───── PLC 24V
            │
            ├─────( + ) Pressure Transducer ( – )───── PLC AI (4–20 mA )
            │
    GND  ───┴───────────────────────────────────────── PLC GND

    Exact pinout varies by connector family (M12, DIN 43650, Packard, etc.). Refer to the product datasheet.

    Quality, Compliance & Reliability

    Every transducer is built under a controlled process with 100% functional testing and calibration across temperature points according to the final specification. Traceability and serialized labels support your field service and warranty programs.

    • Final calibration with NIST-traceable standards
    • Thermal compensation and burn-in strategies tailored to range
    • Ingress protection up to IP67 with molded cable or M12 connectors
    • Documentation: datasheet, test report, and compliance declaration for standard builds

    If your project requires special compliance (e.g., food-contact, oxygen service preparation, or specific EMC standards), let us know. We can evaluate feasibility or provide a compatible transmitter solution.

    Ordering & Bulk Purchasing

    How to Specify

    1. Measurement type: Gauge / Absolute / Differential
    2. Range & units: e.g., 0–16 bar, ±2 kPa, 0–300 kPa abs
    3. Output: 4–20 mA, 0–10 V, 0.5–4.5 V, I²C/SPI
    4. Process connection: G1/4, 1/4-NPT, etc.
    5. Electrical interface: M12, DIN, Packard, cable length
    6. Environment: temperature span, IP level, shock/vibration

    Program Terms

    • Samples available for DFM and validation
    • Tiered pricing for volume schedules
    • Flexible packaging and labeling for your line
    • Rolling forecasts and safety-stock support

    Pressure Transducer vs. Transmitter vs. Switch

    DevicePrimary OutputUse CaseProsConsiderations
    Pressure TransducerAnalog (mA/V) or digital (I²C/SPI)Closed-loop control, measurement, loggingContinuous signal, high resolutionRequires analog/digital input; proper wiring
    Pressure TransmitterConditioned output, industrial housingField installation, long cable runsRuggedized, standardized connectorsLarger form factor; cost vs. bare transducer
    Pressure SwitchOn/Off (relay or transistor)Alarms, interlocks, simple controlSimple, no analog input neededNo continuous measurement

    If you’re migrating from switches to transducers for better control, our team can help tune ranges and filters to stabilize your PID loops.

    Frequently Asked Questions (FAQ)

    How do I choose gauge vs. absolute vs. differential?

    Pick gauge for line pressure relative to ambient (compressors, hydraulics). Use absolute for vacuum or barometric-sensitive measurements. Choose differential for measuring across filters, orifices, or rooms.

    Can you match my connector and pinout exactly?

    Yes. We support M12, DIN 43650, Packard, Deutsch, JST, and custom harnesses with pinouts to your standard, including color coding and labels.

    What environmental protection levels are available?

    Typical builds achieve IP65–IP67 depending on connector and cable sealing. We advise IP67 for wash-down and outdoor use.

    Do you provide calibration certificates?

    We offer factory test reports for each unit and can provide calibration certificates referenced to traceable standards as part of your PPAP or documentation pack.

    Can you help me replace an obsolete model from another brand?

    Yes. Share the part number, electrical output, thread, and range. We will propose a compatible form-fit-function replacement or adapter kit.

    More Refrigerant Sensors Knowledge

    Not sure which sensor is right?

    Get a free initial consultation right now

    has been added to your cart.