Winsen supplies low-range differential pressure (ΔP) transducers designed for HVAC, cleanrooms, filter status, fume hoods, VAV boxes, and process diagnostics. Built on a stable MEMS core with precision temperature compensation, our ΔP devices deliver linear, low-noise signals via 4–20 mA, 0–10 V, ratiometric 0.5–4.5 V, or I²C outputs.

OEM/ODM • Private labeling • Fast lead time

Overview & Working Principle

A differential pressure transducer measures the pressure difference between two ports (High/Low). The sensing diaphragm deflects with ΔP, and the signal-conditioning ASIC converts it into a calibrated electrical signal. Bidirectional variants read both positive and negative pressure relative to the low port—ideal for room pressurization and airflow elements.

Drop-in threads common in hydraulics (G1/4, 1/4-NPT, M14×1.5, etc.)

Outputs for panel meters, PLCs, and SCADA (4–20 mA / 0–10 V)

Option to integrate digital I²C/SPI where available for embedded systems

Pressure Sensor and Transmitter Comparison Overview

CategoryModelPower Supply / OutputDetection RangeAccuracy / NonlinearityPressure ReferenceOperating TemperatureShell MaterialRemarks
Diffused Silicon Pressure SensorWPAK701.5mA / mV-100kPa ~ 0 ~ 10kPa…10MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃High versatility, compact design
WPAK691.5mA / mV-100kPa ~ 0 ~ 10kPa…10MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Similar to WPAK70
WPAK681.5mA / mV-100kPa ~ 0 ~ 10kPa…100MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Extended range version
WPAK671.5mA / mV0 ~ 10kPa…2.5MPa≤±0.3%FSDifferential Pressure-40℃ ~ 120℃For differential applications
WPAK661.5mA or 10V / mV6MPa…60MPa≤±0.3%FSSealed Gauge-40℃ ~ 120℃Sealed design for higher ranges
WPAK651.5mA or 10V / mV-100kPa ~ 0 ~ 10kPa…16MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃General-purpose sensor
WPAK641.5mA or 10V / mV-100kPa ~ 0 ~ 10kPa…25MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Moderate range coverage
WPAK63J1.5mA / mV-100kPa ~ 0 ~ 10kPa…100MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃J-type version for special mounting
WPAK631.5mA or 10V / mV-100kPa ~ 0 ~ 10kPa…100MPa≤±0.3%FSGauge / Absolute / Sealed Gauge-40℃ ~ 120℃Versatile with wide range
Ceramic Pressure SensorWPAH012–20V / mV0 ~ 200kPa…40MPa≤±0.3%FS-40℃ ~ 125℃High chemical resistance
Plastic Sealed Pressure SensorWPAS12Digital and analog15–115kPa-40℃ ~ 125℃Cost-effective, compact
WPAS02Digital and analog10kPa ~ 100kPa-20℃ ~ 80℃Basic sensor for air/gas
WPAS01Digital and analog10kPa ~ 100kPa-40℃ ~ 125℃Robust high-temp tolerance
Diffused Silicon Pressure TransmitterWPCK814–20mA, RS4850 ~ 1m…200mH₂O±0.5%FS / ±1%FSGauge PressureStainless steelFor deep-level and tank level measurements
WPCK624–20mA (Optional)0 ~ 35kPa…25MPa±0.5%FSGauge / Absolute / Sealed GaugeStainless steelWidely compatible, thread options
WPCK084–20mA, RS4850 ~ 200mH₂O±0.5%FSGauge PressureStainless steelExplosion-proof version
WPCK074–20mA, 0.5–4.5V, 0–5V, 1–5V, 0–10V, 1–10V-100kPa ~ 0 ~ 10kPa…100MPa±0.5%FSGauge / Absolute / Sealed GaugeStainless steelFull-range output types
WPCK050.5–4.5V, 0–5V, 1–5V, 0–10V, 1–10V-100kPa ~ 0 ~ 10kPa…100MPa±0.5%FSGauge / Absolute / Sealed GaugeStainless steelVoltage output options
WPCK03I²C, 4–20mA, 0.5–4.5V and more-100kPa ~ 0 ~ 10kPa…100MPa±0.2%FS, ±0.5%FS (custom)Gauge / Absolute / Sealed GaugeStainless steelFlexible signal types, high accuracy
Ceramic Pressure TransmitterWPCH040.5–4.5V (Customizable)0.2MPa…40MPa0.1%FS (Default)Stainless steelHigh precision ceramic core
WPCH014–20mA, 0/1–5/10V, 0.5–4.5V0.2–5MPa0.1% ~ 5.0%FS (Default 2.0%)Stainless steelCustomizable, versatile outputs
WPBH01Proportional voltage (0.5–4.5V)2–400 bar (Customizable)0.5%, 1%, 2% (Default), 3%Stainless steelBroad pressure range
Glass Micro-Fusing TransmitterWPCK89Digital and analog0 ~ 100 / 150 / 250 / 500 psig±1%FSStainless steelExtremely robust and thermally stable

Selection Guide

Use CaseRecommended RangePreferred OutputPorts & ElectricalNotes
Cleanroom pressurization±25…±250 Pa0–10 V or I²CBarbed 4–6 mm; JST/MolexEnable averaging to reduce door-opening spikes.
Filter status (AHU)±250 Pa…±2 kPa4–20 mABarbed ports; M12/DIN via harnessBest for long runs and noisy plant rooms.
VAV & duct airflow±50 Pa…±1 kPa0.5–4.5 V or I²CBoard-level or compact modulePair with flow element; use median filtering.
Fume hood face velocity±50…±500 Pa0–10 VBarbed; shielded cableAuto-zero at start with both ports to ambient.
Process orifice/flow±2…±100 kPa4–20 mAIsolated adapters availableCheck static pressure and media compatibility.

Need RS-485/Modbus or a display? Choose the transmitter package or request a custom electronics stack.

Key Specifications

MeasurementBidirectional differential (High–Low) or unidirectional
Ranges±25 Pa → ±100 kPa (custom on request)
Outputs4–20 mA (2-wire), 0–10 V / 0–5 V, 0.5–4.5 V ratiometric, I²C
Accuracy (typ.)±0.25%FS (options per range)
Stability±0.2%FS/year typical
Response2–10 ms (digital filtering configurable)
Comp. Temp−10…85 °C (options wider)
Operating Temp−20…85 °C air (consult liquid models)
Overload / Burst2× / 5× FS typical (per model)
PortsBarbed 4–6 mm, M5, 1/8-NPT, manifold/custom
ElectricalJST/Molex headers, cable pigtail, M12 via harness
ProtectionReverse polarity; optional hydrophobic filter; IP-rated housings via transmitter

Applications & Industries

HVAC & Building Controls

Room pressurization (positive/negative), stairwell pressurization, AHU filter status, VAV control.

Healthcare & Cleanrooms

ISO/GMP suites and isolation rooms with continuous ΔP monitoring and alarm relays.

Process & Instruments

Orifice ΔP for flow, blower monitoring, burner air control, leak and blockage diagnostics.

Why Global Clients Choose Us?

The company consistently adheres to the quality policy of “Fine Craftsmanship, Scientific Innovation, Pursuit of Excellence, and Value-Added Service.” By formulating production process control plans and work instructions, it has established a standardized, accountable, and regulated process management system. Additionally, the company has independently developed an MES production management system, enabling comprehensive and visual management across the entire workflow.

30+ YEARS OF EXPERIENCE

R&D, manufacture and sales of sensors and sensing solutions.

QUALITY GUARANTEE CONTINOUS IMPROVEMENT

Complete and rigid process flow control, coupled with significant improvements.

INTERNATIONAL MARKET

Deliver sensing products to more than 100 countries and regions.

STABLE SUPPLY CHAIN RELIABLE PRODUCTION

Core components not subject to constraints, advanced equipments for manufaturing and test.

R&D STRENGTH TECHNOLOGY INNOVATION

200+ patents, 180+ R&D team members, self-built labs for continous innovation.

ONE-STOP SERVICE

Professional consultation, fast delivery, 24 hours after-sales support.

Leading the Industry, Innovative & Controllable Technology

With robust R&D capabilities, we maintain sustained input in R&D and unwavering commitment to technological innovation. This not only ensures that we remain at the forefront of industry but also drives continuous innovation, leading the future trend of the sensing industry.

10% R&D Input

The average annual R&D input exceeds 10% of the annual revenue.

5+ R&D Layout

With Zhengzhou headquarters as the core, a nationwide R&D and innovation system is being established, encompassing cities of Shanghai, Wuhan, Shenzhen, and Taiyuan.

180+ R&D Team

There are over 180 R&D personnel, including more than 10 with doctoral degrees and over 50 with master's degrees, who have an average of more than 8 years of experience in sensor development.

20+ Experiment Types

Gas-related, Climatic Environment, EMC, Electrical Performance, Mechanical Performance, etc.

10+ Advanced Laboratories

CNAS Laboratory, MEMS Laboratory, UL Laboratory, Nanocomposite Materials Laboratory, etc.

400+ sets Leading R&D Equipment

Cube Storage, Die Bonder, Lithography Machine, Coating Machine, SMT Placement Machine, Automatic Probe Station, etc.

Request Consultation

    Success! Your message has been sent to us.
    Error! There was an error sending your message.

    Wechat

    Whatsapp

    Integration & Wiring

    4–20 mA (2-wire): Best for long cables and noisy environments; 12–36 VDC loop power with proper loop impedance.

    0–10 V / 0–5 V: Simple panel-meter/DAQ hookup; use high-impedance input (>10 kΩ) and clean supply.

    Ratiometric / I²C: For embedded devices; short leads, stable 5 V, pull-ups on I²C, and cable shielding recommended.

    Example: 0–10 V to PLC
    +24V ── Sensor V+         PLC AI (0–10V) ── Sensor Vout
     GND ── Sensor GND        PLC GND ───────── Sensor GND
     H Port ← High side          L Port ← Low side (reference)

    Pinouts vary by connector (JST/Molex/M12/DIN). Refer to the product datasheet for orientation and wiring.

    Ordering & Bulk Purchasing

    How to Specify

    1. Range & units (e.g., ±50 Pa, ±500 Pa, ±2 kPa, ±100 kPa)
    2. Output (4–20 mA, 0–10 V, 0.5–4.5 V, I²C)
    3. Ports (barbed size, M5, 1/8-NPT, manifold)
    4. Connector (JST/Molex, cable pigtail, M12 via harness)
    5. Environment (temperature, condensation, vibration)
    6. Calibration (zero/span points, filter constants)

    Program Terms

    • Samples for DFM and validation
    • Tiered pricing for volume schedules
    • Private labeling & custom packaging
    • Rolling forecasts with safety stock options

    Differential Pressure Sensor vs Transducer vs Transmitter

    DeviceOutputTypical UseProsConsiderations
    ΔP Sensor (board/compact)Ratiometric / I²C / SPIEmbedded devices, instrumentsSmall, low-power, cost-effectiveRequires host electronics and enclosure
    ΔP Transducer0–10 V / 4–20 mAPLC/DAQ measurementSimple wiring, long cable runsExternal display/relays not included
    ΔP TransmitterConditioned + enclosure (often display/relays)Field installation, panel mountRugged, installer-friendlyLargest size and highest cost

    Not sure which to choose? Share your controller model and mounting location—we’ll recommend the right package.

    Frequently Asked Questions (FAQ)

    How do I perform on-site zeroing?

    Power up and allow 1–5 minutes warm-up. Vent both ports to ambient (tubes off or both open), then press the ZERO key or use the software command. For analog units, trim to 0 V or 4 mA with both ports vented.

    How should I route the tubing for best accuracy?

    Keep H/L tubes equal length, avoid kinks, and mount ports level. Use short runs for faster dynamics and add hydrophobic filters or drip loops to keep moisture out.

    Will long tubing slow the response?

    Yes—added volume and friction create damping. Shorten lines or increase ID for quicker response, and apply 0.5–3 s averaging to stabilize HVAC readings.

    What is the static pressure rating vs. the ΔP range?

    ΔP range is the measurable difference; static pressure is the absolute pressure present on both ports. Verify the sensor’s maximum static rating exceeds your duct or process static pressure.

    How does temperature affect accuracy?

    Sensors are temperature-compensated, but residual error remains. Install away from heat sources, allow warm-up, and request multi-point calibration over your operating band if needed.

    What calibration interval do you recommend?

    Commonly 12 months for HVAC/cleanrooms; 6 months for critical processes. We can provide certificates and help align intervals with your QA procedures.

    More Refrigerant Sensors Knowledge

    Not sure which sensor is right?

    Get a free initial consultation right now

    has been added to your cart.
    Checkout