Water Pressure Sensor | Transducers & Transmitters for Pumps, RO & HVA
Winsen water pressure sensors measure gauge or absolute pressure in pumps, pipelines, RO/UF skids, boilers, and HVAC water loops. Choose rugged industrial transmitters with 4–20 mA / 0–10 V outputs, or OEM sensor cores for compact devices and smart meters.
OEM/ODM • Rotulagem privada • Prazo de entrega rápido
- 0–6 / 0–10 / 0–16 bar typical water ranges
- 4–20 mA / 0–10 V PLC & BMS ready
- SS316L / Ceramic robust wetted parts
- IP-rated field installation









Overview & Types
Water pressure sensors convert hydrostatic or line pressure into a calibrated electrical signal. For industrial water, the common modes are:
Gauge pressure — pipelines, pumps, RO/UF skids, boilers, HVAC water loops.
Absolute pressure — special reference measurements and test benches.
Differential pressure (ΔP) — across filters, membranes and orifices to monitor fouling and flow.
Visão geral do sensor de pressão e comparação de transmissores
| Categoria | Modelo | Fonte de alimentação / saída | Faixa de detecção | Precisão / não linearidade | Referência de pressão | Temperatura operacional | Material da concha | Observações |
| Sensor de pressão difusa de silício | WPAK70 | 1.5mA / MV | -100kpa ~ 0 ~ 10kpa… 10mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Alta versatilidade, design compacto |
| WPAK69 | 1.5mA / MV | -100kpa ~ 0 ~ 10kpa… 10mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Semelhante ao WPAK70 | |
| WPAK68 | 1.5mA / MV | -100kpa ~ 0 ~ 10kpa… 100mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Versão de alcance estendido | |
| WPAK67 | 1.5mA / MV | 0 ~ 10kpa… 2,5mpa | ≤ ± 0,3%Fs | Pressão diferencial | -40 ℃ ~ 120 ℃ | - | Para aplicações diferenciais | |
| WPAK66 | 1.5mA ou 10V / mV | 6mpa… 60mpa | ≤ ± 0,3%Fs | Medidor selado | -40 ℃ ~ 120 ℃ | - | Projeto selado para faixas mais altas | |
| WPEK65 | 1.5mA ou 10V / mV | -100kpa ~ 0 ~ 10kpa… 16mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Sensor de uso geral | |
| WPAK64 | 1.5mA ou 10V / mV | -100kpa ~ 0 ~ 10kpa… 25mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Cobertura de alcance moderada | |
| WOPAK63J | 1.5mA / MV | -100kpa ~ 0 ~ 10kpa… 100mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Versão do tipo j para montagem especial | |
| WPAK63 | 1.5mA ou 10V / mV | -100kpa ~ 0 ~ 10kpa… 100mpa | ≤ ± 0,3%Fs | Medidor / medidor absoluto / selado | -40 ℃ ~ 120 ℃ | - | Versátil com ampla gama | |
| Sensor de pressão de cerâmica | WPAH01 | 2–20V / MV | 0 ~ 200kpa… 40mpa | ≤ ± 0,3%Fs | - | -40 ℃ ~ 125 ℃ | - | Alta resistência química |
| Sensor de pressão selada de plástico | WPAS12 | Digital e analógico | 15–115kpa | - | - | -40 ℃ ~ 125 ℃ | - | Econômico, compacto |
| WPAS02 | Digital e analógico | 10kpa ~ 100kpa | - | - | -20 ℃ ~ 80 ℃ | - | Sensor básico para ar/gás | |
| WPAS01 | Digital e analógico | 10kpa ~ 100kpa | - | - | -40 ℃ ~ 125 ℃ | - | Tolerância robusta de alta temperatura | |
| Transmissor de pressão difusa de silício | WPCK81 | 4–20mA, RS485 | 0 ~ 1m… 200mh₂o | ± 0,5%Fs / ± 1%Fs | Pressão do medidor | - | Aço inoxidável | Para medições de nível de nível profundo e tanque |
| WPCK62 | 4–20mA (opcional) | 0 ~ 35kpa ... 25mpa | ± 0,5%Fs | Medidor / medidor absoluto / selado | - | Aço inoxidável | Amplamente compatível, opções de threads | |
| WPCK08 | 4–20mA, RS485 | 0 ~ 200mh₂o | ± 0,5%Fs | Pressão do medidor | - | Aço inoxidável | Versão à prova de explosão | |
| WPCK07 | 4–20mA, 0,5–4,5V, 0–5V, 1–5V, 0–10V, 1–10V | -100kpa ~ 0 ~ 10kpa… 100mpa | ± 0,5%Fs | Medidor / medidor absoluto / selado | - | Aço inoxidável | Tipos de saída de alcance total | |
| WPCK05 | 0.5–4.5V, 0–5V, 1–5V, 0–10V, 1–10V | -100kpa ~ 0 ~ 10kpa… 100mpa | ± 0,5%Fs | Medidor / medidor absoluto / selado | - | Aço inoxidável | Opções de saída de tensão | |
| WPCK03 | I²C, 4-20mA, 0,5-4,5V e mais | -100kpa ~ 0 ~ 10kpa… 100mpa | ± 0,2%fs, ± 0,5%fs (costume) | Medidor / medidor absoluto / selado | - | Aço inoxidável | Tipos de sinal flexíveis, alta precisão | |
| Transmissor de pressão de cerâmica | WPCH04 | 0.5-4.5V (personalizável) | 0.2mpa… 40mpa | 0.1%fs (padrão) | - | - | Aço inoxidável | Núcleo de cerâmica de alta precisão |
| WPCH01 | 4–20mA, 0/1–5/10V, 0,5–4,5V | 0.2–5mpa | 0.1%~ 5,0%FS (padrão 2,0%) | - | - | Aço inoxidável | Saídas personalizáveis e versáteis | |
| WPBH01 | Tensão proporcional (0,5-4,5V) | 2–400 bar (personalizável) | 0.5%, 1%, 2%(padrão), 3% | - | - | Aço inoxidável | Faixa de pressão ampla | |
| Transmissor de micro-uso de vidro | WPCK89 | Digital e analógico | 0 ~ 100 / 150/250 / 500 psig | ± 1%fs | - | - | Aço inoxidável | Extremamente robusto e termicamente estável |
Guia de seleção
| Caso de uso | Faixa recomendada | Modelo | Saída preferida | Notas |
|---|---|---|---|---|
| Building water / booster sets | 0–10 / 0–16 barras | WPCK05/WPCK07 | 4–20 mA | Snubber for water hammer; shielded cable for EMC. |
| RO/UF membrane racks | 0–6 / 0–10 bar | WPCK62 | 0–10 V ou 4–20 mA | Compact for skids; monitor feed and concentrate lines. |
| Boilers / hot water circuits | 0–16 / 0–25 bar | WPCK03 | 4–20 mA | Select seals for temperature (FKM/PTFE); verify overload. |
| Filter status (ΔP across housing) | ±100…±300 kPa | WPAK67ΔP | 4–20 mA / 0–10 V | Equal-length tubing; add air trap or drip loop. |
| Rough utilities / pulsating pumps | 0–10 / 0–16 barras | WPCH04 | 4–20 mA | Ceramic diaphragm tolerates ripple & particles. |
| OEM smart gauge/head | 0–10 / 0–16 barras | WPAK66 (núcleo) | Nível do conselho | Add your display, electronics, and enclosure. |
Threads: G1/4, G1/2, 1/4-NPT, 1/2-NPT and others. Seals: EPDM (potable), FKM (hot water), PTFE (chemicals) — choose per medium and temperature.
Applications & Industries
Municipal & Building Water
Booster sets, zones, risers and meter pits — stable monitoring and leak detection logic.
RO/UF & Process Skids
Feed/concentrate pressure, membrane ΔP and CIP verification for water treatment lines.
HVAC Water Loops
Chilled/hot water circuits, differential across coils, and pump protection.
Firefighting & Sprinklers
0–16 bar typical with alarm thresholds and event logging to the BMS.
Boilers & Heat Exchangers
Higher ranges and temperature-tolerant seals for steam-side auxiliaries and hot water.
Test Benches
Compact transmitters for flow/pressure rigs with rapid step response.
Por que os clientes globais nos escolhem?
A empresa segue constantemente a política de qualidade de “artesanato fino, inovação científica, busca de excelência e serviço de valor agregado”. Ao formular planos de controle de processos de produção e instruções de trabalho, estabeleceu um sistema de gerenciamento de processos padronizado, responsável e regulamentado. Além disso, a empresa desenvolveu independentemente um sistema de gerenciamento de produção do MES, permitindo um gerenciamento abrangente e visual em todo o fluxo de trabalho.

Mais de 30 anos de experiência
R&D, manufacture and sales of sensors and sensing solutions.
Melhoria contínua de garantia de qualidade
Controle de fluxo completo e rígido do processo, juntamente com melhorias significativas.


MERCADO INTERNACIONAL
Entregue produtos detectados a mais de 100 países e regiões.
Cadeia de suprimentos estável Produção confiável
Os componentes principais não estão sujeitos a restrições, equipamentos avançados para fabricação e teste.


R&D STRENGTH TECHNOLOGY INNOVATION
200+ patents, 180+ R&D team members, self-built labs for continous innovation.
Serviço único
Consulta profissional, entrega rápida, suporte para pós-venda de 24 horas.

Leading the Industry, Innovative & Controllable Technology
With robust R&D capabilities, we maintain sustained input in R&D and unwavering commitment to technological innovation. This not only ensures that we remain at the forefront of industry but also drives continuous innovation, leading the future trend of the sensing industry.
10% R&D Input
The average annual R&D input exceeds 10% of the annual revenue.
5+ R&D Layout
With Zhengzhou headquarters as the core, a nationwide R&D and innovation system is being established, encompassing cities of Shanghai, Wuhan, Shenzhen, and Taiyuan.
180+ R&D Team
There are over 180 R&D personnel, including more than 10 with doctoral degrees and over 50 with master's degrees, who have an average of more than 8 years of experience in sensor development.
Mais de 20 tipos de experimentos
Ambiente climático relacionado a gás, EMC, desempenho elétrico, desempenho mecânico, etc.
Mais de 10 laboratórios avançados
Laboratório CNAS, Laboratório MEMS, Laboratório UL, Laboratório de Materiais Nanocompósitos, etc.
400+ sets Leading R&D Equipment
Armazenamento de cubos, Die Bonder, Máquina de Litografia, máquina de revestimento, máquina de colocação SMT, estação de sonda automática, etc.
Integration & Installation
4–20 mA (2 fios): Best for long noisy runs to PLC/BMS. Use 12–36 VDC loop power and keep loop impedance within spec.
0–10V: Simple to panel meters/DAQ; ensure high-impedance input (>10 kΩ) and clean supply.
Mecânico: Mount away from check/solenoid valves to reduce hammer; add a snubber; orient process port upward when possible to avoid air pockets.
- Confirm overload/burst vs. transient spikes.
- Select seal materials for temperature and chemistry.
- For ΔP tubing, use equal length and add drip loops/air traps.
Ordering & Bulk Purchasing
Como especificar
- Measurement & range (e.g., gauge 0–10/16 bar; ΔP ±200 kPa)
- Output (4–20 mA, 0–10 V, 0.5–4.5 V)
- Process thread (G1/4, G1/2, 1/4-NPT, 1/2-NPT, tri-clamp)
- Connector/cable (M12, DIN, Deutsch/Packard, pigtail)
- Medium & temperature (potable, RO, hot water, CIP/SIP)
- Docs (test report, calibration cert, labeling)
Termos do programa
- Amostras para validação e testes de bancada
- Preços escalonados para programações de volume
- Private labeling & custom packaging
- Previsões contínuas com opções de ações de segurança
Sensor de pressão diferencial vs transdutor vs transmissor
| Dispositivo | Saída | Uso típico | Prós | Considerações |
|---|---|---|---|---|
| Sensor ΔP (placa/compacto) | Raciométrico / I²C / SPI | Dispositivos incorporados, instrumentos | Pequeno, de baixo consumo de energia e econômico | Requer componentes eletrônicos e gabinete do host |
| Transdutor ΔP | 0–10 V / 4–20 mA | Medição CLP/DAQ | Fiação simples, cabos longos | Display/relés externos não incluídos |
| Transmissor ΔP | Condicionado + gabinete (geralmente display/relés) | Instalação em campo, montagem em painel | Robusto e fácil de instalar | Maior tamanho e maior custo |
Não tem certeza de qual escolher? Compartilhe o modelo do seu controlador e o local de montagem – recomendaremos o pacote certo.
Perguntas frequentes (FAQ)
What range should I choose for water systems?
0–6 bar for RO/UF, 0–10 bar for building water and HVAC loops, 0–16 bar for boosters/sprinklers, and up to 25 bar for boilers. Use compound ranges if slight vacuum occurs.
Which diaphragm and seals are best?
SS316L suits most water; ceramic improves tolerance to pulsation/solids. Choose EPDM for potable water, FKM for hot water, and PTFE for chemical compatibility.
How to mitigate water hammer?
Install a snubber/restrictor, place the sensor away from fast valves, and consider accumulators; verify overload and burst ratings.
Can I monitor filter fouling?
Yes. Use a differential pressure transducer across the filter housing to trend ΔP and plan cartridge changeouts.
Do you offer sanitary or flush-diaphragm builds?
Yes. We can customize tri-clamp and flush-mount process connections for food/pharma water with CIP/SIP.
What documentation can I get?
Standard test reports are included; calibration certificates and serialized labels are available per your QA program.
























