Water Pressure Sensor | Transducers & Transmitters for Pumps, RO & HVA
Winsen water pressure sensors measure gauge or absolute pressure in pumps, pipelines, RO/UF skids, boilers, and HVAC water loops. Choose rugged industrial transmitters with 4–20 mA / 0–10 V outputs, or OEM sensor cores for compact devices and smart meters.
OEM/ODM • Prywatne oznakowanie • Szybki czas realizacji
- 0–6 / 0–10 / 0–16 bar typical water ranges
- 4–20 mA / 0–10 V PLC & BMS ready
- SS316L / Ceramic robust wetted parts
- IP-rated field installation









Overview & Types
Water pressure sensors convert hydrostatic or line pressure into a calibrated electrical signal. For industrial water, the common modes are:
Gauge pressure — pipelines, pumps, RO/UF skids, boilers, HVAC water loops.
Absolute pressure — special reference measurements and test benches.
Differential pressure (ΔP) — across filters, membranes and orifices to monitor fouling and flow.
Przegląd porównania czujnika ciśnienia i nadajnika
| Kategoria | Model | Zasilacz / moc wyjściowa | Zakres wykrywania | Dokładność / nieliniowość | Odniesienie do ciśnienia | Temperatura robocza | Materiał skorupy | Uwagi |
| Rozproszony czujnik ciśnienia silikonu | WPAK70 | 1,5 mA / mv | -100KPA ~ 0 ~ 10KPA… 10MPA | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Wysoka wszechstronność, kompaktowa konstrukcja |
| WPAK69 | 1,5 mA / mv | -100KPA ~ 0 ~ 10KPA… 10MPA | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Podobne do WPAK70 | |
| WPAK68 | 1,5 mA / mv | -100KPA ~ 0 ~ 10KPA… 100MPA | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Wersja o rozszerzonym zakresie | |
| WPAK67 | 1,5 mA / mv | 0 ~ 10kpa… 2,5MPA | ≤ ± 0,3%FS | Presja różnicowa | -40 ℃ ~ 120 ℃ | - - | Do zastosowań różnicowych | |
| WPAK66 | 1,5 mA lub 10 V/mV | 6MPA… 60MPA | ≤ ± 0,3%FS | Uszczelniony miernik | -40 ℃ ~ 120 ℃ | - - | Uszczelniona konstrukcja dla wyższych zakresów | |
| Wpek65 | 1,5 mA lub 10 V/mV | -100 kPa ~ 0 ~ 10 kPa…16 MPa | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Czujnik ogólnego przeznaczenia | |
| Wpak64 | 1,5 mA lub 10 V/mV | -100 kPa ~ 0 ~ 10 kPa…25 MPa | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Umiarkowany zasięg | |
| Wopak63j | 1,5 mA / mv | -100KPA ~ 0 ~ 10KPA… 100MPA | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Wersja typu J do montażu specjalnego | |
| WPAK63 | 1,5 mA lub 10 V/mV | -100KPA ~ 0 ~ 10KPA… 100MPA | ≤ ± 0,3%FS | Miernik / bezwzględny / uszczelniony wskaźnik | -40 ℃ ~ 120 ℃ | - - | Wszechstronny i szeroki asortyment | |
| Ceramiczny czujnik ciśnienia | WPAH01 | 2–20 V/mV | 0 ~ 200kPa…40MPa | ≤ ± 0,3%FS | - - | -40 ℃ ~ 125 ℃ | - - | Wysoka odporność chemiczna |
| Plastikowy czujnik ciśnienia | WPAS12 | Cyfrowe i analogowe | 15–115 kPa | - - | - - | -40 ℃ ~ 125 ℃ | - - | Ekonomiczny, kompaktowy |
| WPAS02 | Cyfrowe i analogowe | 10 kPa ~ 100 kPa | - - | - - | -20 ℃ ~ 80 ℃ | - - | Podstawowy czujnik powietrza/gazu | |
| Wpas01 | Cyfrowe i analogowe | 10 kPa ~ 100 kPa | - - | - - | -40 ℃ ~ 125 ℃ | - - | Solidna tolerancja na wysokie temperatury | |
| Rozproszony nadajnik na ciśnienie silikonu | WPCK81 | 4–20 mA, RS485 | 0 ~ 1m…200mH₂O | ±0,5% FS / ±1% FS | Ciśnienie miernika | - - | Stal nierdzewna | Do pomiarów na głębokich poziomach i w zbiornikach |
| WPCK62 | 4–20 mA (opcjonalnie) | 0 ~35kPa…25MPa | ± 0,5% pełnej skali | Miernik / bezwzględny / uszczelniony wskaźnik | - - | Stal nierdzewna | Szeroko kompatybilne opcje gwintów | |
| WPCK08 | 4–20 mA, RS485 | 0 ~ 200mH₂O | ± 0,5% pełnej skali | Ciśnienie miernika | - - | Stal nierdzewna | Wersja przeciwwybuchowa | |
| WPCK07 | 4–20 mA, 0,5–4,5 V, 0–5 V, 1–5 V, 0–10 V, 1–10 V | -100KPA ~ 0 ~ 10KPA… 100MPA | ± 0,5% pełnej skali | Miernik / bezwzględny / uszczelniony wskaźnik | - - | Stal nierdzewna | Typy wyjściowe pełnego zasięgu | |
| WPCK05 | 0.5–4,5 V, 0–5 V, 1–5 V, 0–10 V, 1–10 V | -100KPA ~ 0 ~ 10KPA… 100MPA | ± 0,5% pełnej skali | Miernik / bezwzględny / uszczelniony wskaźnik | - - | Stal nierdzewna | Opcje wyjściowe napięcia | |
| WPCK03 | I²C, 4–20 mA, 0,5–4,5 V i więcej | -100KPA ~ 0 ~ 10KPA… 100MPA | ± 0,2%FS, ± 0,5%FS (niestandardowe) | Miernik / bezwzględny / uszczelniony wskaźnik | - - | Stal nierdzewna | Elastyczne typy sygnałów, wysoka dokładność | |
| Nadajnik ciśnienia ceramicznego | WPCH04 | 0.5–4,5 V (możliwe do dostosowania) | 0.2mpa… 40mpa | 0.1%FS (domyślnie) | - - | - - | Stal nierdzewna | Wysoka precyzyjna ceramiczna rdzeń |
| WPCH01 | 4–20MA, 0/1–5/10 V, 0,5–4,5 V. | 0.2–5mpa | 0.1%~ 5,0%FS (domyślnie 2,0%) | - - | - - | Stal nierdzewna | Konfigurowalne, wszechstronne wyjścia | |
| WPBH01 | Napięcie proporcjonalne (0,5–4,5 V) | 2–400 bar (dostosowywany) | 0.5%, 1%, 2%(domyślnie), 3% | - - | - - | Stal nierdzewna | Szeroki zakres ciśnienia | |
| Szklany nadajnik mikro | WPCK89 | Cyfrowe i analogowe | 0 ~ 100 /150 /250 /500 psig | ± 1%fs | - - | - - | Stal nierdzewna | Niezwykle solidne i stabilne termicznie |
Przewodnik wyboru
| Przypadek użycia | Zalecany zakres | Model | Preferowane wyjście | Notatki |
|---|---|---|---|---|
| Building water / booster sets | 0–10 / 0–16 barów | WPCK05 / WPCK07 | 4–20 mA | Snubber for water hammer; shielded cable for EMC. |
| RO/UF membrane racks | 0–6 / 0–10 bar | WPCK62 | 0–10 V lub 4–20 mA | Compact for skids; monitor feed and concentrate lines. |
| Boilers / hot water circuits | 0–16 / 0–25 bar | WPCK03 | 4–20 mA | Select seals for temperature (FKM/PTFE); verify overload. |
| Filter status (ΔP across housing) | ±100…±300 kPa | WPAK67 ΔP | 4–20 mA / 0–10 V | Equal-length tubing; add air trap or drip loop. |
| Rough utilities / pulsating pumps | 0–10 / 0–16 barów | WPCH04 | 4–20 mA | Ceramic diaphragm tolerates ripple & particles. |
| OEM smart gauge/head | 0–10 / 0–16 barów | WPAK66 (rdzeń) | Poziom zarządu | Add your display, electronics, and enclosure. |
Threads: G1/4, G1/2, 1/4-NPT, 1/2-NPT and others. Seals: EPDM (potable), FKM (hot water), PTFE (chemicals) — choose per medium and temperature.
Applications & Industries
Municipal & Building Water
Booster sets, zones, risers and meter pits — stable monitoring and leak detection logic.
RO/UF & Process Skids
Feed/concentrate pressure, membrane ΔP and CIP verification for water treatment lines.
HVAC Water Loops
Chilled/hot water circuits, differential across coils, and pump protection.
Firefighting & Sprinklers
0–16 bar typical with alarm thresholds and event logging to the BMS.
Boilers & Heat Exchangers
Higher ranges and temperature-tolerant seals for steam-side auxiliaries and hot water.
Dlaczego globalni klienci wybierają nas?
Firma konsekwentnie przestrzega polityki jakościowej „drobnego rzemiosła, innowacji naukowych, dążenia do doskonałości i usługi o wartości dodanej”. Sformułując plany kontroli procesu produkcji i instrukcje pracy, ustanowił standardowy, odpowiedzialny i regulowany system zarządzania procesami. Ponadto firma niezależnie opracowała system zarządzania produkcją MES, umożliwiając kompleksowe i wizualne zarządzanie w całym przepływie pracy.

Ponad 30 lat doświadczenia
R&D, manufacture and sales of sensors and sensing solutions.
Gwarancja jakości ciągła poprawa
Pełna i sztywna kontrola przepływu procesu, w połączeniu ze znaczącą ulepszeniami.


Rynek międzynarodowy
Dostarczaj produkty czujnikowe do ponad 100 krajów i regionów.
STABILNY ŁAŃCUCH DOSTAW NIEZAWODNA PRODUKCJA
Podstawowe komponenty nie podlegające ograniczeniom, zaawansowane urządzenia do produkcji i testowania.


R&D STRENGTH TECHNOLOGY INNOVATION
200+ patents, 180+ R&D team members, self-built labs for continous innovation.
Usługa jednokrotna
Profesjonalne konsultacje, szybka dostawa, 24-godzinne wsparcie posprzedażowe.

Leading the Industry, Innovative & Controllable Technology
With robust R&D capabilities, we maintain sustained input in R&D and unwavering commitment to technological innovation. This not only ensures that we remain at the forefront of industry but also drives continuous innovation, leading the future trend of the sensing industry.
10% R&D Input
The average annual R&D input exceeds 10% of the annual revenue.
5+ R&D Layout
With Zhengzhou headquarters as the core, a nationwide R&D and innovation system is being established, encompassing cities of Shanghai, Wuhan, Shenzhen, and Taiyuan.
180+ R&D Team
There are over 180 R&D personnel, including more than 10 with doctoral degrees and over 50 with master's degrees, who have an average of more than 8 years of experience in sensor development.
Ponad 20 rodzajów eksperymentów
Związane z gazem, środowisko klimatyczne, EMC, wydajność elektryczna, wydajność mechaniczna itp.
Ponad 10 zaawansowanych laboratoriów
CNAS Laboratory, MEMS Laboratory, UL Laboratory, Nanokomposite Materials Laboratory itp.
400+ sets Leading R&D Equipment
Storage kostki, Die Bonder, Maszyna litograficzna, maszyna do powlekania, maszyna do umieszczania SMT, automatyczna stacja sondy itp.
Integration & Installation
4–20 mA (2-przewodowe): Best for long noisy runs to PLC/BMS. Use 12–36 VDC loop power and keep loop impedance within spec.
0–10 V: Simple to panel meters/DAQ; ensure high-impedance input (>10 kΩ) and clean supply.
Mechanical: Mount away from check/solenoid valves to reduce hammer; add a snubber; orient process port upward when possible to avoid air pockets.
- Confirm overload/burst vs. transient spikes.
- Select seal materials for temperature and chemistry.
- For ΔP tubing, use equal length and add drip loops/air traps.
Ordering & Bulk Purchasing
Jak określić
- Measurement & range (e.g., gauge 0–10/16 bar; ΔP ±200 kPa)
- Output (4–20 mA, 0–10 V, 0.5–4.5 V)
- Process thread (G1/4, G1/2, 1/4-NPT, 1/2-NPT, tri-clamp)
- Connector/cable (M12, DIN, Deutsch/Packard, pigtail)
- Medium & temperature (potable, RO, hot water, CIP/SIP)
- Docs (test report, calibration cert, labeling)
Warunki programu
- Próbki do testów walidacyjnych i laboratoryjnych
- Warstwowe ceny dla harmonogramów wolumenów
- Private labeling & custom packaging
- Prognozy kroczące z opcjami na akcje zabezpieczające
Czujnik różnicy ciśnień vs przetwornik vs przetwornik
| Urządzenie | Wyjście | Typowe zastosowanie | Plusy | Rozważania |
|---|---|---|---|---|
| Czujnik ΔP (płytka/kompakt) | Ratiometryczny / I²C / SPI | Urządzenia wbudowane, instrumenty | Mały, energooszczędny, ekonomiczny | Wymaga elektroniki hosta i obudowy |
| Przetwornik ΔP | 0–10 V / 4–20 mA | Pomiar PLC/DAQ | Proste okablowanie, długie przebiegi kabli | Zewnętrzny wyświetlacz/przekaźniki nie wchodzą w skład zestawu |
| Nadajnik ΔP | Kondycjonowane + obudowa (często wyświetlacz/przekaźniki) | Instalacja w terenie, montaż panelowy | Wytrzymały, łatwy w montażu | Największy rozmiar i najwyższy koszt |
Nie wiesz, który wybrać? Udostępnij model kontrolera i miejsce montażu – polecimy odpowiedni pakiet.
Często zadawane pytania (FAQ)
What range should I choose for water systems?
0–6 bar for RO/UF, 0–10 bar for building water and HVAC loops, 0–16 bar for boosters/sprinklers, and up to 25 bar for boilers. Use compound ranges if slight vacuum occurs.
Which diaphragm and seals are best?
SS316L suits most water; ceramic improves tolerance to pulsation/solids. Choose EPDM for potable water, FKM for hot water, and PTFE for chemical compatibility.
How to mitigate water hammer?
Install a snubber/restrictor, place the sensor away from fast valves, and consider accumulators; verify overload and burst ratings.
Can I monitor filter fouling?
Yes. Use a differential pressure transducer across the filter housing to trend ΔP and plan cartridge changeouts.
Do you offer sanitary or flush-diaphragm builds?
Yes. We can customize tri-clamp and flush-mount process connections for food/pharma water with CIP/SIP.
What documentation can I get?